We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Background: Uptake of self-testing and self-management of oral coagulation has remained inconsistent, despite good evidence of their effectiveness. To clarify the value of self-monitoring of oral anticoagulation, we did a meta-analysis of individual patient data addressing several important gaps in the evidence, including an estimate of the effect on time to death, first major haemorrhage, and thromboembolism. Methods: We searched Ovid versions of Embase (1980-2009) and Medline (1966-2009), limiting searches to randomised trials with a maximally sensitive strategy. We approached all authors of included trials and requested individual patient data: primary outcomes were time to death, first major haemorrhage, and first thromboembolic event. We did prespecified subgroup analyses according to age, type of control-group care (anticoagulation-clinic care vs primary care), self-testing alone versus self-management, and sex. We analysed patients with mechanical heart valves or atrial fibrillation separately. We used a random-effect model method to calculate pooled hazard ratios and did tests for interaction and heterogeneity, and calculated a time-specific number needed to treat. Findings: Of 1357 abstracts, we included 11 trials with data for 6417 participants and 12 800 person-years of follow-up. We reported a significant reduction in thromboembolic events in the self-monitoring group (hazard ratio 0·51; 95 CI 0·31-0·85) but not for major haemorrhagic events (0·88, 0·74-1·06) or death (0·82, 0·62-1·09). Participants younger than 55 years showed a striking reduction in thrombotic events (hazard ratio 0·33, 95 CI 0·17-0·66), as did participants with mechanical heart valve (0·52, 0·35-0·77). Analysis of major outcomes in the very elderly (age ≥85 years, n=99) showed no significant adverse effects of the intervention for all outcomes. Interpretation: Our analysis showed that self-monitoring and self-management of oral coagulation is a safe option for suitable patients of all ages. Patients should also be offered the option to self-manage their disease with suitable health-care support as back-up. Funding: UK National Institute for Health Research (NIHR) Technology Assessment Programme, UK NIHR National School for Primary Care Research. © 2012 Elsevier Ltd.

Original publication

DOI

10.1016/S0140-6736(11)61294-4

Type

Journal article

Journal

The Lancet

Publication Date

01/01/2012

Volume

379

Pages

322 - 334